HTML5 Webook
92/248

ilspmuPcuardyHlllilOABABABAA6 ■● Designed for high capacity using a radial piston high-pressure pump with standard accessories. ● Only a 4-way manual direction-control valve (HOV-410) is attached as a standard feature.■MP-40 series hydraulic circuit diagrams lispmuPaunaMspmuPyrettaBseireSPMSspmuPcirtceEspmuPacepSreooCModel code structureMP-40CTwo-Stage Electric Pumps (30/55 kW) Make-to-order product*The load current means the peak current (reference value). It varies depending on the operating status.■MP-40 series● Two MP-20 pumps and a tank are combined so that the discharge volume is about twice as much as that of an MP-20 pump.● If a solenoid valve is used for press work or the like, it is recommended to provide a pressure reducing circuit to reduce shock during switching.● To change the valve after purchase, replacement or modification of the valve unit mounting base is necessary.MP-75 series■ Motor specifications (MP-40 series)■ Pump specificationsLoad current 50 Hz60 Hz128.0136.0Effective oil volumeLAttached operating valveBHV-410370SOW-R-48-2 & GCH-48T1000HOV-410No.Name1Oil tank4Motor5Electric magneticswitch6Push-buttonswitch12High/low-pressurecheckvalve13High-pressure safety valveRE-2614Low-pressure safetyvalveRUN-21015Unloadingvalve18PressureswitchDPGS-7022Direction-control valveBHV-41027Airbreather29Oil level gauge34Oil drain port35Returnport36Outlet portBHV-410SOW-R-48-2GCH-48THOV-41015MPa72MPa9.5MPa8.5MPa72MPa16MPaElectric Pumps● Do not supply power continuously to the solenoid valve of the MP-40S for one minute or longer while pressure is applied. Otherwise, switching by the spool is not possible.* No power cable is included with the product.* The direction-control valve of the S model is not wired.* The pump stops automatically at the preset pressure for the pressure switch. To reboot the pump, use the push-button switch (No. 6).Electric pumpMP-40CMP-40STypeC:For double-acting cylinders (manual direction-control valve)S:For double-acting cylindersSeries No.40/75(solenoid operated directionvalve)*For the MP-40 only* The above numbers do not correspond to the part numbers of the product. For the part numbers of the product, see the operation manual.TypeFully-enclosed fan-cooled typeMaximum operating pressure MPaModelHigh pressureLow pressureAt high pressureAt low pressureMP-40CMP-40S70MP-75C■MP-40CVoltage(Number of phases) V200 (3 phases) Discharge volume L/min (50/60 Hz) 20.0/24.0140.0/168.019.0/23.01242.0190Number of revolutions rpm50 Hz60 Hz15001800Approx.weightkg21003200NotesWith refill portRc11/2Rc11/2Rc11/4■MP-75C hydraulic circuit diagramOutputkWRated current 50 Hz60 Hz30120.0112.0Outlet portRcTank oil volumeLHydraulic oil6201 1/4ISO VG461300No.79E since202591

元のページ  ../index.html#92

このブックを見る